論文種別 原著(症例報告除く)
言語種別 英語
査読の有無 その他(不明)
表題 The diagnostic potential of combined quantitative polymerase chain reaction and next-generation sequencing using the same primers for periprosthetic joint infection.
掲載誌名 正式名:Microbiology spectrum
略  称:Microbiol Spectr
ISSNコード:21650497/21650497
掲載区分国外
巻・号・頁 pp.Online ahead of print
著者・共著者 Narumi Ueda, Jun Inoue, Kazuyuki Okuda, Hirokazu Iida
発行年月 2026/07
概要 Next-generation sequencing (NGS) enables the detection of specific pathogens unidentifiable by conventional cultures, but its application in orthopedics remains inconsistent due to background contamination and irreproducible findings. This study evaluated the diagnostic performance of a novel workflow combining broad-range 16S rRNA gene quantitative PCR (qPCR) screening with downstream NGS, focusing on bacterial biomass thresholds. The qPCR assay demonstrated excellent intrarater reliability, with an intraclass correlation coefficient (ICC) of 0.961 (95% confidence interval, 0.881 to 0.997). Based on serially diluted positive controls, a quantitative threshold of 10⁵ CFU/mL was established as the minimum concentration required for the consistent detection of fastidious taxa, such as Escherichia coli. When evaluated against conventional cultures using 95 sonicate fluid and 276 pre/intraoperative tissue samples, the qPCR assay achieved a sensitivity of 80% and a specificity of 72%. Subsequent NGS sequencing of 26 clinical samples and 9 controls showed concordance in 4 of 6 culture-positive infected cases with NGS taxonomy, whereas the remaining discrepancies were likely attributable to culture-based phenotypic misidentification. Notably, among the qPCR-positive cases, three were culture-negative, including two hip prosthesis loosening cases exhibiting polymicrobial profiles, and one post-traumatic osteoarthritis case harboring low-level Staphylococcus. Crucially, this post-traumatic patient developed delayed periprosthetic joint infection (PJI) 2 years post-surgery, with cultures identifying Staphylococcus previously detected by the initial NGS analysis. Integrating qPCR screening with targeted NGS effectively refines pathogen identification, filters environmental artifacts, and overcomes the diagnostic limitations of culture-negative infections in orthopedic practice.IMPORTANCENext-generation sequencing (NGS) enables the detection of specific pathogens in clinical samples that are not identifiable by conventional methods. However, NGS applications in orthopedics have not been quantitatively evaluated, and findings have been inconsistent owing to contaminants and the presence of non-credible causative organisms. These factors primarily stem from the failure to evaluate low-biomass samples and the absence of proper controls, such as negative controls or mock community DNA samples. This study demonstrates that interpreting results from low-biomass samples requires careful consideration because NGS relies on relative bacterial abundances; distinguishing likely pathogens from contaminants is particularly challenging when bacterial loads are low. We demonstrated that combining NGS with quantitative PCR (qPCR) and applying a Cq cutoff can reduce false positives.
DOI 10.1128/spectrum.04128-25
PMID 42517638